Airtècnics logo
Air Curtains Ventilation Air Disinfection

Air Curtains Specialist - Industrial Ventilation

  • Català
  • English
  • Español

  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  Login

Air Curtains Specialist - Industrial Ventilation

  • Products
    • Air Curtains
      Air Curtains
    • Air Purifier and Disinfection Units
      Air Purifier and Disinfection Units
    • Air Handling Units
      Air Handling Units
    • Heat Recovery Units
      Heat Recovery Units
    • Ventilation Units
      Ventilation Units
    • Fan Heaters
      Fan Heaters
    • Axial Fans
      Axial Fans
    • Radial fans
      Radial fans
    • Centrifugal Fans
      Centrifugal Fans
    • In Line Fans
      In Line Fans
    • Exhaust Fans Units
      Exhaust Fans Units
    • Cross-Flow Fans
      Cross-Flow Fans
    • Filters and Filter Units
      Filters and Filter Units
    • Dampers and Shutters
      Dampers and Shutters
    • Rotary Actuators
      Rotary Actuators
    • Regulation
      Regulation
    • Pressure Switches and Sensors
      Pressure Switches and Sensors
    • See all products
  • Technology
    • Air curtains: Foundations

      • What is an air curtain?
      • Are air curtains effective?
      • How air curtains work?
      • Air curtains: Technology
      • Advantages and benefits of air curtains
      • Air curtains: Applications
      • Installation examples
      • Selection factors of air curtains
      • Air curtains control and regulation
      • Heat pump air curtains
      • EC air curtains
    • Airtècnics Air Curtains

      • Characteristics
      • R+D+i UPC university
      • Selection chart
      • Models and applications
      • Control and regulation
      • Accessories
    • OH Technology

      • Hydroxyl Radicals Technology
      • OH technology application sectors
      • What is OH technology for?
      • OH technology against bacteria: Tests
      • OH technology against viruses: Tests
      • Is OH technology effective in educational centers?
      • Safety of long-term exposure to hydroxyl radicals
    • Ventilation

      • Fans: Overview
      • Heat recovery: Overview
      • Heat recovery: Types
      • EC fans: Overview
      • EC fans: Advantages
      • Rotary actuators for dampers
      • Fan speed controllers
      • Air Handling Unit: Types AHU
  • Novelties
    • News

      • Air curtains to improve customer comfort at Mercat de Sant Antoni
      • Air curtains for cold stores in Colombia
      • Retrofit projects with EC Fan Grid save energy
      • Invisair air curtains for totally integrated installations
      • Airtrack: new Airtècnics’ air curtain for refrigerated vehicles
      • Windbox air curtains in the logistics centre of the Lulu Logistics Group in Qatar
      • Multiple Windbox air curtain in Brasov's Airport in Romania
      • Indoor air quality and health
    • Newsletters

      • Newsletter July 2022
      • Newsletter June 2022
      • Newsletter May 2022
      • Newsletter April 2022
      • Newsletter March 2022
      • Newsletter February 2022
      • Newsletter January 2022
      • Newsletter December 2021
    • Top Works

      • Eiffel Tower, Paris (France)
      • W hotel, Dubai (UAE)
      • Nike store, Milan (Italy)
      • Sheikh Jaber Al-Ahmad Cultural Centre, Kuwait (Kuwait)
      • Mango shop, Platja d'Aro (Spain)
      • Vodafone store, Barcelona (Spain)
      • Stratford station, London (United Kingdom)
      • Union Square building, Aberdeen (United Kingdom)
  • Applications
    • Configuration and Selection Apps

      • Air Curtain Selection and Configuration Program
      • Air Curtain Reference Information
      • Air Curtain Spare parts
      • Air Curtain Accessories list
    • Calculations

      • Air Curtain Door Loss Calculation
      • Air Curtain Comparative AC vs EC
      • Air Curtain Comparative Electrical Heated vs Heat Pump
      • Air Curtain Equivalent water valve size
      • Heating Air temperature increasing
    • Product Illustration

      • Infographics - Virtual Product Applications
  • Gallery
    • Installations
    • Virtual Installations
    • Videos
  • References
  • Downloads
  • Company
    • Airtècnics
    • Staff
    • Rosenberg Group
    • Work with Us
  • Contact
    • Contact Us
    • Air Curtains Distributors
    • Air Purifier Distributors
  • Català
  • English
  • Español
  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  1. Home
  2. Products
  3. Air Curtains
  4. Recessed Air Curtains
  5. Air curtain Recessed Dam
Index
Air Curtains

Air Curtains

Air Purifier and Disinfection Units

Air Purifier and Disinfection Units

Air Handling Units

Air Handling Units

Heat Recovery Units

Heat Recovery Units

Ventilation Units

Ventilation Units

Fan Heaters

Fan Heaters

Axial Fans

Axial Fans

Radial fans

Radial fans

Centrifugal Fans

Centrifugal Fans

In Line Fans

In Line Fans

Exhaust Fans Units

Exhaust Fans Units

Cross-Flow Fans

Cross-Flow Fans

Filters and Filter Units

Filters and Filter Units

Dampers and Shutters

Dampers and Shutters

Rotary Actuators

Rotary Actuators

Regulation

Regulation

Pressure Switches and Sensors

Pressure Switches and Sensors

Air curtain Recessed Dam

DAM is an air curtain from the standard range that stands out for its versatility and the design that can be fitted into a false ceiling, with a full view of the diffuser grille. The air intake grille is maintenance-free and is integrated into a single white frame, or the one you prefer on request.

Air curtain Recessed Dam
Air curtain Recessed Dam
Previous Next


  • Compact and low profile recessed air curtain with full grille view.
  • Self-supporting casing construction made of galvanized steel plate, ready to be installed recessed in a false ceiling.
  • Inlet grille (free of maintenance) made with aluminium profiles and blow-out nozzle, integrated in a single white frame colour RAL 9016. Other colours are available on request.
  • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. EC models assembled with very low consumption efficiency fans.
  • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil.
  • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…)

Datasheet Recessed Dam
Recessed Air Curtains
Air Curtains Catalogue

 BIM Files
 Request more information
  • 50Hz
  • 60Hz
    • Unheated
    • Electrical Heating
    • Water Heating
    Model
    Nominal Airflow
    m³/h
    Recommended Installation Height
    m
    RDAM M 1000 A18002,5-3,5
    RDAM M 1500 A27002,5-3,5
    RDAM M 2000 A36002,5-3,5
    RDAM M 2500 A45002,5-3,5
    RDAM ECM 1000 A18402,5-3,8
    RDAM ECM 1500 A27602,5-3,8
    RDAM ECM 2000 A36802,5-3,8
    RDAM ECM 2500 A46002,5-3,8
    RDAM G 1000 A24003-4
    RDAM G 1500 A32003-4
    RDAM G 2000 A48003-4
    RDAM G 2500 A56003-4
    RDAM ECG 1000 A27003-4,2
    RDAM ECG 1500 A36003-4,2
    RDAM ECG 2000 A54003-4,2
    RDAM ECG 2500 A63003-4,2
    Model
    Nominal Airflow
    m³/h
    Electrical Heating Capacity 400Vx3
    kW
    Recommended Installation Height
    m
    RDAM M 1000 E18003/6/92,5-3,5
    RDAM M 1500 E27004/8/122,5-3,5
    RDAM M 2000 E36006/12/182,5-3,5
    RDAM M 2500 E45006/12/182,5-3,5
    RDAM ECM 1000 E18403/6/92,5-3,8
    RDAM ECM 1500 E27604/8/122,5-3,8
    RDAM ECM 2000 E36806/12/182,5-3,8
    RDAM ECM 2500 E46006/12/182,5-3,8
    RDAM G 1000 E24005/10/153-4
    RDAM G 1500 E32007,5/15/22,53-4
    RDAM G 2000 E480010/20/303-4
    RDAM G 2500 E560010/20/303-4
    RDAM ECG 1000 E27005/10/153-4,2
    RDAM ECG 1500 E36007,5/15/22,53-4,2
    RDAM ECG 2000 E540010/20/303-4,2
    RDAM ECG 2500 E630010/20/303-4,2
    Model
    Nominal Airflow
    m³/h
    Heating Capacity 80/60ºC
    kW
    Heating Capacity 60/40ºC
    kW
    Heating Capacity 50/40ºC
    kW
    Recommended Installation Height
    m
    RDAM M 1000 P641660-8,56-2,5-3,5
    RDAM M 1000 P541660--8,522,5-3,5
    RDAM M 1000 P8616609,17--2,5-3,5
    RDAM M 1500 P642490-13,69-2,5-3,5
    RDAM M 1500 P542490--14,342,5-3,5
    RDAM M 1500 P86249014,26--2,5-3,5
    RDAM M 2000 P643320-18,26-2,5-3,5
    RDAM M 2000 P543320--18,652,5-3,5
    RDAM M 2000 P86332020,65--2,5-3,5
    RDAM M 2500 P644150-22,12-2,5-3,5
    RDAM M 2500 P544150--24,322,5-3,5
    RDAM M 2500 P86415026,92--2,5-3,5
    RDAM ECM 1000 P641720-8,77-2,5-3,8
    RDAM ECM 1000 P541720--8,742,5-3,8
    RDAM ECM 1000 P8617209,38--2,5-3,8
    RDAM ECM 1500 P642580-14,02-2,5-3,8
    RDAM ECM 1500 P542580--14,712,5-3,8
    RDAM ECM 1500 P86258014,58--2,5-3,8
    RDAM ECM 2000 P643440-18,7-2,5-3,8
    RDAM ECM 2000 P543440--19,132,5-3,8
    RDAM ECM 2000 P86344021,12--2,5-3,8
    RDAM ECM 2500 P644300-23,33-2,5-3,8
    RDAM ECM 2500 P544300--24,952,5-3,8
    RDAM ECM 2500 P86430027,53--2,5-3,8
    RDAM G 1000 P642250-10,42-3-4
    RDAM G 1000 P542250--10,563-4
    RDAM G 1000 P86225011,04--3-4
    RDAM G 1500 P643000-15,47-3-4
    RDAM G 1500 P543000--16,373-4
    RDAM G 1500 P86300016,02--3-4
    RDAM G 2000 P644500-22,29-3-4
    RDAM G 2000 P544500--23,153-4
    RDAM G 2000 P86450024,92--3-4
    RDAM G 2500 P645250-26,61-3-4
    RDAM G 2500 P545250--28,763-4
    RDAM G 2500 P86525031,16--3-4
    RDAM ECG 1000 P642550-11,27-3-4,2
    RDAM ECG 1000 P542550--11,53-4,2
    RDAM ECG 1000 P86255011,89--3-4,2
    RDAM ECG 1500 P643400-16,77-3-4,2
    RDAM ECG 1500 P543400--17,863-4,2
    RDAM ECG 1500 P86340017,29--3-4,2
    RDAM ECG 2000 P645100-24,14-3-4,2
    RDAM ECG 2000 P545100--25,243-4,2
    RDAM ECG 2000 P86510026,86--3-4,2
    RDAM ECG 2500 P645950-28,84-3-4,2
    RDAM ECG 2500 P545950--31,383-4,2
    RDAM ECG 2500 P86595033,63--3-4,2
    • Unheated
    • Electrical Heating
    • Water Heating
    Model
    Nominal Airflow
    m³/h
    Recommended Installation Height
    m
    RDAM ECM 1000 A18402,5-3,8
    RDAM ECM 1500 A27602,5-3,8
    RDAM ECM 2000 A36802,5-3,8
    RDAM ECM 2500 A46002,5-3,8
    RDAM ECG 1000 A27003-4,2
    RDAM ECG 1500 A36003-4,2
    RDAM ECG 2000 A54003-4,2
    RDAM ECG 2500 A63003-4,2
    Model
    Nominal Airflow
    m³/h
    Electrical Heating Capacity 400Vx3
    kW
    Recommended Installation Height
    m
    RDAM ECM 1000 E18403/6/92,5-3,8
    RDAM ECM 1500 E27604/8/122,5-3,8
    RDAM ECM 2000 E36806/12/182,5-3,8
    RDAM ECG 1000 E27005/10/153-4,2
    RDAM ECG 1500 E36007,5/15/22,53-4,2
    RDAM ECG 2000 E540010/20/303-4,2
    RDAM ECG 2500 E630010/20/303-4,2
    Model
    Nominal Airflow
    m³/h
    Heating Capacity 80/60ºC
    kW
    Heating Capacity 60/40ºC
    kW
    Heating Capacity 50/40ºC
    kW
    Recommended Installation Height
    m
    RDAM ECM 1000 P641720-8,77-2,5-3,8
    RDAM ECM 1000 P541720--8,742,5-3,8
    RDAM ECM 1000 P8617209,38--2,5-3,8
    RDAM ECM 1500 P642580-14,02-2,5-3,8
    RDAM ECM 1500 P542580--14,712,5-3,8
    RDAM ECM 1500 P86258014,58--2,5-3,8
    RDAM ECM 2000 P643440-18,7-2,5-3,8
    RDAM ECM 2000 P543440--19,132,5-3,8
    RDAM ECM 2000 P86344021,12--2,5-3,8
    RDAM ECM 2500 P644300-23,33-2,5-3,8
    RDAM ECM 2500 P544300--24,952,5-3,8
    RDAM ECM 2500 P86430027,53--2,5-3,8
    RDAM ECG 1000 P642550-11,27-3-4,2
    RDAM ECG 1000 P542550--11,53-4,2
    RDAM ECG 1000 P86255011,89--3-4,2
    RDAM ECG 1500 P643400-16,77-3-4,2
    RDAM ECG 1500 P543400--17,863-4,2
    RDAM ECG 1500 P86340017,29--3-4,2
    RDAM ECG 2000 P645100-24,14-3-4,2
    RDAM ECG 2000 P545100--25,243-4,2
    RDAM ECG 2000 P86510026,86--3-4,2
    RDAM ECG 2500 P645950-28,84-3-4,2
    RDAM ECG 2500 P545950--31,383-4,2
    RDAM ECG 2500 P86595033,63--3-4,2
  • Images
  • Dimensions
  • 3D View
Air curtain Recessed Dam - Dimensions
Products
Air Curtains
Air Purifier and Disinfection Units
Air Handling Units
Heat Recovery Units
Ventilation Units
Fan Heaters
Axial Fans
Radial fans
Centrifugal Fans
In Line Fans
Exhaust Fans Units
Cross-Flow Fans
Filters and Filter Units
Dampers and Shutters
Rotary Actuators
Regulation
Pressure Switches and Sensors

Air Curtains
Standard Air Curtains
Recessed Air Curtains
Decorative, Bespoke and Customized Air Curtains
Air curtains with Disinfection and Purification System
Heat Pump and Energy Saving Air Curtains
Industrial Air Curtains and Cold Store Air Curtains
Insect control Air Curtains
Revolving Door and Tailor Made Air Curtains
Economic Low Cost Air Curtains

About us
Airtècnics history
Rosenberg group
Contact
Aircurtains Distributors
Air Purifier Distributors

Downloads
Air curtains catalogues
Ventilation catalogues
BIM Air Curtains
Air curtains price list
Technical documentation
Quality certificates

Featured content
Clever advanced control
Air curtains selection program
Air curtains installations: References
Air curtains photo gallery
Technology
What is an air curtain?
How air curtains work?
Advantages and benefits of air curtains
Heat pump air curtains
EC air curtains
Airtècnics air curtains
Ventilation

Outlet


Legal terms
Privacy policy
Legal notice
Conditions of sale
Cookies policy
+34 93 715 99 88 +34 93 715 99 88
airtecnics@airtecnics.com

Request more information

The message been successfully submitted.

Request more information

If you want more information, fill the form and we contact with you.






Check this box if you like to receive professional information.

In accordance with the established RGPD (General Data Protection Regulation), we inform you that your personal data collected by means of this form will be incorporated in a file held by MOTORS I VENTILADORS, S.L., which has the purpose of enabling the management and commercial relations, informative or contractual and in any form and medium, including electronic means, about the products and/or services you are interested in. Your data will not be disclosed to third parties without your consent expressly stated, except in cases provided by law or requisitions of the competent public Administration.

You therefore expressly authorise us to use and process your personal data for the aforementioned purposes.

At any time, you may exercise your rights of access, rectification, erasure, restriction of processing, portability and object of your personal data processing. We request that you notify us to MOTORS I VENTILADORS, S.L. C/ Conca de Barberà, 6, Pol. Ind. Pla de la Bruguera 08211 CASTELLAR DEL VALLÈS (Barcelona) or send an email to the following address airtecnics@airtecnics.com

I accept and give my consent for the abovementioned purposes. (*)
We use our own and third-party cookies to analyze our services and show you advertising related to your preferences based on a profile made from your browsing habits (for example, pages visited). You can get more information and set your preferences HERE.