INVISAIR air curtain is designed to be installed invisibly in false ceilings and columns or drawers around the door. It is an ideal solution for those entrances that for architectural reasons require an air curtain installation that is fully integrated into the interior design of the building.
It can be vertically or horizontally mounted. The air flow of Invisair follows a straight line from the air inlet grille to the to the discharge. Inlet area inside a bulkhead or column should be designed with suitable grille provided by others.
Its energy saving heat pump compatible version achieves a reduction of up to 70% in consumption and CO2 emissions (in heating mode). Internal prefilter included.
Includes only heating direct expansion coil with installed temperature sensors.
Advanced Plug&Play control. Includes: Advanced PRO control with LCD display and integrated thermostat, door contact, 7m RJ11 cable and remote control.
DX 1:1
Ready to connect to MIDEA Inverter outdoor heat pump unit (R410A) with expansion valve, not included, the customer should purchase it. Requires DX Interface KIT adapted for air curtain and programmable control.
DX VRF
Ready to connect to MIDEA VRF outdoor heat pump unit (R410A), not included, the customer should purchase it.
Requires DX Interface KIT with expansion valve adapted for air curtain.

| Model | Nominal Airflow m³/h | Outdoor Unit 230Vx1 | Outdoor Unit 400Vx3 | Recommended Installation Range m |
|---|---|---|---|---|
| IECG 1000 DX10-MD | 2190 | MOD30U-36HFN1-QRD0 | MOD30U-36HFN1-RRD0 | 3-4,2 |
| IECG 3000 DX32/2-MD | 5840 | 2x MOD30U-48HFN1-QRD0 | 2x MOD30U-48HFN1-RRD0 | 3-4,2 |
| Model | Nominal Airflow m³/h | Recommended Installation Range m |
|---|---|---|
| IECG 1000 VRF10-MD | 2190 | 3-4,2 |
| IECG 1500 VRF13-MD | 2820 | 3-4,2 |
| IECG 1500 VRF15-MD | 2820 | 3-4,2 |
| IECG 2000 VRF24-MD | 4380 | 3-4,2 |
| IECG 2500 VRF25-MD | 5110 | 3-4,2 |
| IECG 2500 VRF29-MD | 5110 | 3-4,2 |
| IECG 3000 VRF29-MD | 5840 | 3-4,2 |
| IECG 3000 VRF34-MD | 5840 | 3-4,2 |
| Model | Nominal Airflow m³/h | Outdoor Unit 230Vx1 | Outdoor Unit 400Vx3 | Recommended Installation Range m |
|---|---|---|---|---|
| IECG 1000 DX10-MD | 2190 | MOD30U-36HFN1-QRD0 | MOD30U-36HFN1-RRD0 | 3-4,2 |
| IECG 3000 DX32/2-MD | 5840 | 2x MOD30U-48HFN1-QRD0 | 2x MOD30U-48HFN1-RRD0 | 3-4,2 |
| Model | Nominal Airflow m³/h | Recommended Installation Range m |
|---|---|---|
| IECG 1000 VRF10-MD | 2190 | 3-4,2 |
| IECG 1500 VRF13-MD | 2820 | 3-4,2 |
| IECG 1500 VRF15-MD | 2820 | 3-4,2 |
| IECG 2000 VRF24-MD | 4380 | 3-4,2 |
| IECG 2500 VRF25-MD | 5110 | 3-4,2 |
| IECG 2500 VRF29-MD | 5110 | 3-4,2 |
| IECG 3000 VRF29-MD | 5840 | 3-4,2 |
| IECG 3000 VRF34-MD | 5840 | 3-4,2 |