Efficiency against Volatile Organic Compound (VOC) deodorization - Test result Korea Conformity Laboratories

Wellisair: Efficiency against Volatile Organic Compound (VOC)

 

Test report (nº 026961): : April 1st, 2016 Korea Conformity Laboratories (KCL).

 

Scope: measure the effectiveness of the Wellisair for the deodorization of most important Volatile Organic Compound (VOC).

 

Procedure:

  • Test Mode: S/W On (Rated Air Flow Rate)
  • Gas Analyser: Gas detector tube Gastec CV-100
  • Test Method: Test chamber of 1m3 for 4 hours
  • Test Conditions: 20ºC 45% R.H.
 

 

 

 

 

 

 

 

 

 

 

Results:

Deodorization Rate Reduction (%)

Time

Ammonia (NH3)

Toluene (C6H5CH3)

Formaldehyde (HCHO)

1h

30%

60%

25%

2h

50%

>99,5%

40%

3h

65%

>99,5%

55%

4h

80%

>99,5%

65%

 

 

 

 

 

 

 

 

 

Conclusions: Wellisair air disinfection had a deodorization rate of 80% for the Ammonia and of 99% for the Formaldehyde after 4 hours of treatment. The deodorization rate was greater than of 99,5% for the Toluene in only 2 hours.