SMART air curtain bridges the gap between standard and decorative models, making it ideal for commercial and public spaces seeking efficient, sustainable climate control without compromising interior design. It combines advanced technology with a sleek, contemporary aesthetic, featuring a smooth front panel and a concealed top air intake that hides the grille for a clean, elegant appearance.
Its energy saving heat pump compatible version achieves a reduction of up to 70% in consumption and CO2 emissions (in heating mode).
Sensors pre-installed in the direct expansion coil. As an option, under request, it can also work in cold mode (refrigeration), with optional condensate water pump.Internal pre-filter included.
Advanced Plug&Play control. Includes: Advanced PRO control with LCD display and integrated thermostat, door contact, 7m RJ11 cable and remote control.
DX 1:1
Ready to connect to HITACHI Inverter outdoor heat pump unit (R32) and expansion valve not included, the customer should purchase it. Requires HITACHI DX Interface KIT adapted for air curtain with expansion valve and programmable control.
DX VRV
Ready to connect to HITACHI VRF outdoor heat pump unit (R410A) and expansion valve not included, the customer should purchase it. Requires HITACHI VRF Interface KIT adapted for air curtain with expansion valve and programmable control.

| Model | Nominal Airflow m³/h | Outdoor Unit 230Vx1 | Outdoor Unit 400Vx3 | Recommended Installation Range m |
|---|---|---|---|---|
| SMART ECM 1000 DX8-HI | 1640 | RAS-3HVNC1 | - | 2,5-3,8 |
| SMART ECM 1500 DX11-HI | 2460 | RAS-4HVNC1E | RAS-4HNC1E | 2,5-3,8 |
| SMART ECM 2000 DX16-HI | 3280 | RAS-6HVNC1E | RAS-6HNC1E | 2,5-3,8 |
| SMART ECM 2500 DX21-HI | 4100 | - | RAS-8HNCE | 2,5-3,8 |
| SMART ECM 3000 DX26-HI | 4920 | - | RAS-10HNCE | 2,5-3,8 |
| SMART ECG 1000 DX8-HI | 2190 | RAS-3HVNC1 | - | 3-4,2 |
| SMART ECG 1500 DX13-HI | 2920 | RAS-5HVNC1E | RAS-5HNC1E | 3-4,2 |
| SMART ECG 1500 DX15-HI | 2920 | RAS-6HVNC1E | RAS-6HNC1E | 3-4,2 |
| SMART ECG 2000 DX22-HI | 4380 | - | RAS-8HNCE | 3-4,2 |
| SMART ECG 2500 DX22-HI | 5110 | - | RAS-8HNCE | 3-4,2 |
| SMART ECG 2500 DX28-HI | 5110 | - | RAS-10HNCE | 3-4,2 |
| SMART ECG 3000 DX28-HI | 5840 | - | RAS-10HNCE | 3-4,2 |
| Model | Nominal Airflow m³/h | Recommended Installation Range m |
|---|---|---|
| SMART ECM 1000 VRF8-HI | 1640 | 2,5-3,8 |
| SMART ECM 1500 VRF12-HI | 2460 | 2,5-3,8 |
| SMART ECM 2000 VRF16-HI | 3280 | 2,5-3,8 |
| SMART ECM 2500 VRF21-HI | 4100 | 2,5-3,8 |
| SMART ECM 2000 VRF19-HI | 3280 | 2,5-3,8 |
| SMART ECM 3000 VRF26-HI | 4920 | 2,5-3,8 |
| SMART ECM 2500 VRF24-HI | 4100 | 2,5-3,8 |
| SMART ECG 1000 VRF10-HI | 2190 | 3-4,2 |
| SMART ECG 1500 VRF13-HI | 2920 | 3-4,2 |
| SMART ECG 1500 VRF15-HI | 2920 | 3-4,2 |
| SMART ECG 2000 VRF20-HI | 4380 | 3-4,2 |
| SMART ECG 2000 VRF24-HI | 4380 | 3-4,2 |
| SMART ECG 2500 VRF25-HI | 5110 | 3-4,2 |
| SMART ECG 2500 VRF29-HI | 5110 | 3-4,2 |
| SMART ECG 3000 VRF29-HI | 5840 | 3-4,2 |
| Model | Nominal Airflow m³/h | Outdoor Unit 230Vx1 | Outdoor Unit 400Vx3 | Recommended Installation Range m |
|---|---|---|---|---|
| SMART ECM 1000 DX8-HI | 1640 | RAS-3HVNC1 | - | 2,5-3,8 |
| SMART ECM 1500 DX11-HI | 2460 | RAS-4HVNC1E | RAS-4HNC1E | 2,5-3,8 |
| SMART ECM 2000 DX16-HI | 3280 | RAS-6HVNC1E | RAS-6HNC1E | 2,5-3,8 |
| SMART ECM 2500 DX21-HI | 4100 | - | RAS-8HNCE | 2,5-3,8 |
| SMART ECM 3000 DX26-HI | 4920 | - | RAS-10HNCE | 2,5-3,8 |
| SMART ECG 1000 DX8-HI | 2190 | RAS-3HVNC1 | - | 3-4,2 |
| SMART ECG 1500 DX13-HI | 2920 | RAS-5HVNC1E | RAS-5HNC1E | 3-4,2 |
| SMART ECG 1500 DX15-HI | 2920 | RAS-6HVNC1E | RAS-6HNC1E | 3-4,2 |
| SMART ECG 2000 DX22-HI | 4380 | - | RAS-8HNCE | 3-4,2 |
| SMART ECG 2500 DX22-HI | 5110 | - | RAS-8HNCE | 3-4,2 |
| SMART ECG 2500 DX28-HI | 5110 | - | RAS-10HNCE | 3-4,2 |
| SMART ECG 3000 DX28-HI | 5840 | - | RAS-10HNCE | 3-4,2 |
| Model | Nominal Airflow m³/h | Recommended Installation Range m |
|---|---|---|
| SMART ECM 1000 VRF8-HI | 1640 | 2,5-3,8 |
| SMART ECM 1500 VRF12-HI | 2460 | 2,5-3,8 |
| SMART ECM 2000 VRF16-HI | 3280 | 2,5-3,8 |
| SMART ECM 2500 VRF21-HI | 4100 | 2,5-3,8 |
| SMART ECM 2000 VRF19-HI | 3280 | 2,5-3,8 |
| SMART ECM 3000 VRF26-HI | 4920 | 2,5-3,8 |
| SMART ECM 2500 VRF24-HI | 4100 | 2,5-3,8 |
| SMART ECG 1000 VRF10-HI | 2190 | 3-4,2 |
| SMART ECG 1500 VRF13-HI | 2920 | 3-4,2 |
| SMART ECG 1500 VRF15-HI | 2920 | 3-4,2 |
| SMART ECG 2000 VRF20-HI | 4380 | 3-4,2 |
| SMART ECG 2000 VRF24-HI | 4380 | 3-4,2 |
| SMART ECG 2500 VRF25-HI | 5110 | 3-4,2 |
| SMART ECG 2500 VRF29-HI | 5110 | 3-4,2 |
| SMART ECG 3000 VRF29-HI | 5840 | 3-4,2 |