Airtècnics logo
Air Curtains Ventilation Air Disinfection

Air Curtains Specialist - Industrial Ventilation

  • Català
  • English
  • Español

  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  Login

Air Curtains Specialist - Industrial Ventilation

  • Products
    • Air curtains
      Air curtains
    • Air Handling Units
      Air Handling Units
    • Heat recovery units
      Heat recovery units
    • Air purifier and disinfection units
      Air purifier and disinfection units
    • Ventilation units
      Ventilation units
    • Filters and filter units
      Filters and filter units
    • Fan heaters
      Fan heaters
    • Axial fans
      Axial fans
    • Radial fans
      Radial fans
    • Centrifugal fans
      Centrifugal fans
    • In line fans
      In line fans
    • Exhaust fans units
      Exhaust fans units
    • Cross-flow fans
      Cross-flow fans
    • Dampers and shutters
      Dampers and shutters
    • Rotary actuators
      Rotary actuators
    • Controllers
      Controllers
    • Pressure switches and sensors
      Pressure switches and sensors
    • See all products
  • Technology
    • Air curtains: Foundations

      • What is an air curtain?
      • Are air curtains effective?
      • How air curtains work?
      • Air curtains: Technology
      • Advantages and benefits of air curtains
      • Air curtains: Applications
      • Installation examples
      • Selection factors of air curtains
      • Air curtains control and modulation
      • Heat pump air curtains
      • EC air curtains
    • Airtècnics Air Curtains

      • Characteristics
      • R+D+i UPC university
      • Selection chart
      • Models and applications
      • Control system
      • Accessories
    • OH Technology

      • Hydroxyl Radicals Technology
      • OH technology application sectors
      • What is OH technology for?
      • OH technology against bacteria: Tests
      • OH technology against viruses: Tests
      • Is OH technology effective in educational centers?
      • Safety of long-term exposure to hydroxyl radicals
    • Ventilation

      • Fans: Overview
      • Heat recovery: Overview
      • Heat recovery: Types
      • EC fans: Overview
      • EC fans: Advantages
      • Rotary actuators for dampers
      • Fan speed controllers
      • Air Handling Unit: Types AHU
      • ECFanGrid: overview
  • Novelties
    • News

      • New control Clever PRO, the revolution in controllers
      • Airtècnics returns to C&R at IFEMA from November 18th to 20th
      • New Horizontal Fan Heater 450 for heating large industrial spaces
      • Rund air curtains in the Grand Palais in Paris
      • Airtècnics will be present in the sixth EFINTEC energetic fair
      • Multiple custom Zen air curtains in a supermarket chain in Germany
      • New Rosenberg's PlugFan
      • Low-cost air curtains? You get what you pay for
    • Newsletters

      • Newsletter September 2025
      • Newsletter July 2025
      • Newsletter June 2025
      • Newsletter May 2025
      • Newsletter April 2025
      • Newsletter March 2025
      • Newsletter February 2025
      • Newsletter January 2025
    • Top Works

      • W hotel, Dubai (UAE)
      • Sheikh Jaber Al-Ahmad Cultural Centre, Kuwait (Kuwait)
      • Nike store, Milan (Italy)
      • Mango shop, Platja d'Aro (Spain)
      • Vodafone store, Barcelona (Spain)
      • Stratford station, London (United Kingdom)
      • Union Square building, Aberdeen (United Kingdom)
      • National Audit Office, London (United Kingdom)
  • Applications
    • Configuration and Selection Apps

      • Air Curtain Selection and Configuration Program
      • Air Curtain Reference Information
      • Air Curtain Spare parts
      • Air Curtain Accessories list
    • Calculations

      • Air Curtain Door Loss Calculation
      • Air Curtain Comparative AC vs EC
      • Air Curtain Comparative Electrical Heated vs Heat Pump
      • Air Curtain Equivalent water valve size
      • Heating Air temperature increasing
    • Product Illustration

      • Infographics - Virtual Product Applications
  • Gallery
    • Installations
    • Virtual Installations
    • Videos
  • References
  • Downloads
  • Company
    • Airtècnics
    • Staff
    • Rosenberg Group
    • Work with Us
  • Contact
    • Contact Us
    • Air Curtains Distributors
    • Air Purifier Distributors
  • Català
  • English
  • Español
  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  1. Home
  2. Products
  3. Controllers
  4. Advanced Control
  5. ADVANCED PRO Control
Index
Air curtains

Air curtains

Air Handling Units

Air Handling Units

Heat recovery units

Heat recovery units

Air purifier and disinfection units

Air purifier and disinfection units

Ventilation units

Ventilation units

Filters and filter units

Filters and filter units

Fan heaters

Fan heaters

Axial fans

Axial fans

Radial fans

Radial fans

Centrifugal fans

Centrifugal fans

In line fans

In line fans

Exhaust fans units

Exhaust fans units

Cross-flow fans

Cross-flow fans

Dampers and shutters

Dampers and shutters

Rotary actuators

Rotary actuators

Controllers

Controllers

Pressure switches and sensors

Pressure switches and sensors

ADVANCED PRO Control

ADVANCED PRO Control
ADVANCED PRO Control
ADVANCED PRO Control
Previous Next


The Advanced PRO control is designed to meet customer needs with semi-automatic, energy-efficient operation. It has been 100% designed and programmed by Airtecnics to be compatible with all ranges of air curtains and replaces the previous controllers.

This control is included in the Optima and Optima recessed, Aris, and TOP air curtain models.

Datasheet Advanced PRO
PRO Control range

 Request more information
Watch video
 

Controllers PRO range: Advanced Control

ADVANCED PRO



A single advanced control for the entire range

Advanced Pro replaces and improves all controls from the previous basic Airtècnics range of 2 and 5 speeds
(no heating, water heating, electric heating, DX heating), Hand Auto, and Interface. Now, all adjustments in one.




Interface and Control Panel

2.8” LCD screen with backlight and capacitive touch buttons.

Infrared remote control.

The LCD screen displays the fan speed, heating stage, setpoint ambient temperature, optional exterior temperature,
door status and external signals, as well as alarms and errors.

Alarm and error codes: Overheating, heating blocked, anti-freeze, fire alarm, communication error...




Connectivity

Plug & Play connection with RJ11 cable.

Automatic initialization with detection of connected hardware, and configuration according to the detected devices.

Power RJ11 24V DC + RS485 Communications.




Temperature and Door Sensors Included

Advanced Pro integrates an ambient temperature sensor and includes a door sensor.
Together with the set point temperature, they form a system that allows for the adjustment of ventilation and heating, saving energy.




Semi-Automatic ECO Mode

With the temperature sensors (one inside included in Advanced Pro, and the other external optional),
several heating control functions can be performed:
modulating the temperature, programming Boost opening (increases the set point temperature by 2°C)...

With the door contact installed, different speeds and heating stages can be programmed according to the door status (open/closed).

Also, there is a door delay, where the unit operates with the door closed for the programmed time.




3 menu levels

User menu for setting the set temperature and ventilation and heating according to the door status.

Quick access for setting the set temperature.

Internal parameter configuration menu:

  • Door delay
  • Maintenance programming
  • Speed and heating limitation
  • Control memo
  • Temperature units
  • Aauto-cooling program
  • Control lock
  • Boost mode




Simple, discreet and compact

The control housing is specifically designed to protect the electronics. It contains several ventilation slots to ensure optimal temperature for internal components.

The new electronics are designed to be more robust, adding electrical and electronic protections, Poke-yoke connections, and protected with varnish to improve corrosion resistance and extend lifespan. The circuit board is fixed in the front housing, and the box closure can be reinforced with an additional security screw.

The box is designed for cable connections to the circuit board to be made from different access points, either through the main housing or the rear cover. It features several pre-cut openings and break zones for cable entry, facilitating installation.

Ready for wall installation and easy to open for electronic maintenance.

 

 

  • Video
Products
Air curtains
Air Handling Units
Heat recovery units
Air purifier and disinfection units
Ventilation units
Filters and filter units
Fan heaters
Axial fans
Radial fans
Centrifugal fans
In line fans
Exhaust fans units
Cross-flow fans
Dampers and shutters
Rotary actuators
Controllers
Pressure switches and sensors

Air Curtains
Standard air curtains
Recessed air curtains
Decorative, bespoke and customized air curtains
Industrial air curtains and cold store air curtains
Revolving door and tailor made air curtains
Insect control air curtains
Heat pump and energy saving air curtains
Air curtains with disinfection and purification system
Economic low cost air curtains

About us
Airtècnics history
Rosenberg group
Contact
Aircurtains Distributors
Air Purifier Distributors

Downloads
Air curtains catalogues
Ventilation catalogues
BIM Air Curtains
Air curtains price list
Technical documentation
Quality certificates

Featured content
Clever advanced control
Air curtains selection program
Air curtains installations: References
Air curtains photo gallery
Technology
What is an air curtain?
How air curtains work?
Advantages and benefits of air curtains
Heat pump air curtains
EC air curtains
Airtècnics air curtains
Ventilation

Outlet


Legal terms
Privacy policy
Legal notice
Conditions of sale
Cookies policy
+34 93 715 99 88 +34 93 715 99 88
airtecnics@airtecnics.com
We use our own and third-party cookies to analyze our services and show you advertising related to your preferences based on a profile made from your browsing habits (for example, pages visited). You can get more information and set your preferences HERE.