Airtècnics logo
Air Curtains Fans Ventilation Actuators

Air Curtains Specialist - Industrial Ventilation

  • Català
  • English
  • Español

  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  Login

Air Curtains Specialist - Industrial Ventilation

  • Products
    • Air Curtains
      Air Curtains
    • Air Purifier and Disinfection Units
      Air Purifier and Disinfection Units
    • Air Handling Units
      Air Handling Units
    • Heat Recovery Units
      Heat Recovery Units
    • Ventilation Units
      Ventilation Units
    • Axial Fans
      Axial Fans
    • Radial fans
      Radial fans
    • Centrifugal Fans
      Centrifugal Fans
    • In Line Fans
      In Line Fans
    • Exhaust Fans Units
      Exhaust Fans Units
    • Cross-Flow Fans
      Cross-Flow Fans
    • Fan Heaters
      Fan Heaters
    • Filters and Filter Units
      Filters and Filter Units
    • Dampers and Shutters
      Dampers and Shutters
    • Rotary Actuators
      Rotary Actuators
    • Regulation
      Regulation
    • Pressure Switches and Sensors
      Pressure Switches and Sensors
    • See all products
  • Technology
    • Air curtains: Foundations

      • What is an air curtain?
      • Are air curtains effective?
      • How air curtains work?
      • Air curtains: Technology
      • Advantages and benefits of air curtains
      • Air curtains: Applications
      • Installation examples
      • Selection factors of air curtains
      • Air curtains control and regulation
      • Heat pump air curtains
      • EC air curtains
    • Airtècnics Air Curtains

      • Characteristics
      • R+D+i UPC university
      • Selection chart
      • Models and applications
      • Control and regulation
      • Accessories
    • Wellisair Technology

      • Wellisair: Hydroxyl Radicals Technology
      • Wellisair application sectors
      • What is Wellisair technology for?
      • Wellisair against bacteria: Tests
      • Wellisair against viruses: Tests
      • Wellisair vs Coronavirus - COVID-19
      • Is Wellisair effective in educational centers?
      • Safety of long-term exposure to hydroxyl radicals
    • Ventilation

      • Fans: Overview
      • Heat recovery: Overview
      • Heat recovery: Types
      • EC fans: Overview
      • EC fans: Advantages
      • Rotary actuators for dampers
      • Fan speed controllers
  • Novelties
    • News

      • New industrial air curtains with heat pump
      • Salamandra hall for concerts installs air purifier K7 to ensure safe culture
      • The Spanish government updates the RITE indoor air quality regulation standard
      • Insect control air curtains for a honey producer. Case study
      • Decorative Zen air curtains for the accesses of the parking in Al Zahia City Center mall in Sharjah
      • Advantages of installing an air curtain with heat pump
      • Healthier gyms thanks to K7 air and surface purifier
      • Most common mistakes in air curtain installations
    • Newsletters

      • Newsletter April 2021
      • Newsletter March 2021
      • Newsletter February 2021
      • Newsletter January 2021
      • Newsletter December 2020
      • Newsletter November 2020
      • Newsletter December 2019
      • Newsletter November 2019
    • Top Works

      • Eiffel Tower, Paris (France)
      • W hotel, Dubai (UAE)
      • Sheikh Jaber Al-Ahmad Cultural Centre, Kuwait (Kuwait)
      • Nike store, Milan (Italy)
      • Mango shop, Platja d'Aro (Spain)
      • Aldi supermarket, Madrid (Spain)
      • Vodafone store, Barcelona (Spain)
      • Stratford station, London (United Kingdom)
  • Applications
    • Air Curtain - Selection and Configuration Program
    • Air Curtain - Reference Information
    • Air Curtain - Door Loss Calculation
    • Air Curtain - Comparative AC vs EC
    • Air Curtain - Comparative Electrical Heated vs Heat Pump
    • Calculation - Air temperature increasing
    • Infographics - Virtual Product Applications
  • Gallery
    • Installations
    • Virtual Installations
    • Wellisair Installations
    • Videos
  • References
  • Downloads
  • Company
    • Airtècnics
    • Staff
    • Rosenberg Group
    • Work with Us
  • Contact
    • Contact Us
    • Air Curtains Distributors
    • Wellisair Distributors
  • Català
  • English
  • Español
  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  1. Home
  2. Products
  3. Ventilation Units
  4. Ventilation boxes
Index
Air Curtains

Air Curtains

Air Purifier and Disinfection Units

Air Purifier and Disinfection Units

Air Handling Units

Air Handling Units

Heat Recovery Units

Heat Recovery Units

Ventilation Units

Ventilation Units

Axial Fans

Axial Fans

Radial fans

Radial fans

Centrifugal Fans

Centrifugal Fans

In Line Fans

In Line Fans

Exhaust Fans Units

Exhaust Fans Units

Cross-Flow Fans

Cross-Flow Fans

Fan Heaters

Fan Heaters

Filters and Filter Units

Filters and Filter Units

Dampers and Shutters

Dampers and Shutters

Rotary Actuators

Rotary Actuators

Regulation

Regulation

Pressure Switches and Sensors

Pressure Switches and Sensors

Ventilation boxes

Airbox.jpg
Ventilation unit Airbox
Low noise units variable flow
Airbox-Duo.jpg
Ventilation unit Airbox Duo
With double fan
Kanalbox.jpg
Ventilation unit Kanalbox
With conventional motor
VariAirbox.jpg
Ventilation unit Variairbox
With integrated regulation and speed controller
KleenBox.jpg
High efficiency Kleenbox air purifier unit with HEPA absolute filtration
Air purifier low noise units variable flow
KleenBox-Vertical.jpg
High efficiency Kleenbox air purifier vertical unit with HEPA absolute filtration
Air purifier low noise vertical units variable flow
Airbox-IDA.jpg
Ventilation unit Airbox IDA
To obey the requirements of the new RITE
Unobox-ME.jpg
Ventilation unit Unobox ME
Low noise units and variable flow for high temperatures
Unobox.jpg
Ventilation units Unobox & EC-Unobox
With backward curved impellers of high performance
Airbox-transmision.jpg
Ventilation unit Belt Driven Airbox
Belt-driven ventilation units
Products
Air Curtains
Air Purifier and Disinfection Units
Air Handling Units
Heat Recovery Units
Ventilation Units
Axial Fans
Radial fans
Centrifugal Fans
In Line Fans
Exhaust Fans Units
Cross-Flow Fans
Fan Heaters
Filters and Filter Units
Dampers and Shutters
Rotary Actuators
Regulation
Pressure Switches and Sensors

Air Curtains
Standard Air Curtains
Recessed Air Curtains
Decorative, Bespoke and Customized Air Curtains
Air curtains with Disinfection and Purification System
Heat Pump and Energy Saving Air Curtains
Industrial Air Curtains and Cold Store Air Curtains
Insect control Air Curtains
Revolving Door and Tailor Made Air Curtains
Economic Low Cost Air Curtains

About us
Airtècnics history
Rosenberg group
Contact
Aircurtains Distributors
Wellisair Distributors

Downloads
Air curtains catalogues
Ventilation catalogues
BIM Air Curtains
Air curtains price list
Technical documentation
Quality certificates

Featured content
Clever advanced control
Air curtains selection program
Air curtains installations: References
Air curtains photo gallery
Technology
What is an air curtain?
How air curtains work?
Advantages and benefits of air curtains
Heat pump air curtains
EC air curtains
Airtècnics air curtains
Ventilation

Outlet


+34 93 715 99 88 +34 93 715 99 88
airtecnics@airtecnics.com

Request more information

The message been successfully submitted.

Request more information

If you want more information, fill the form and we contact with you.






Check this box if you like to receive professional information.

In accordance with the established RGPD (General Data Protection Regulation), we inform you that your personal data collected by means of this form will be incorporated in a file held by MOTORS I VENTILADORS, S.L., which has the purpose of enabling the management and commercial relations, informative or contractual and in any form and medium, including electronic means, about the products and/or services you are interested in. Your data will not be disclosed to third parties without your consent expressly stated, except in cases provided by law or requisitions of the competent public Administration.

You therefore expressly authorise us to use and process your personal data for the aforementioned purposes.

At any time, you may exercise your rights of access, rectification, erasure, restriction of processing, portability and object of your personal data processing. We request that you notify us to MOTORS I VENTILADORS, S.L. C/ Conca de Barberà, 6, Pol. Ind. Pla de la Bruguera 08211 CASTELLAR DEL VALLÈS (Barcelona) or send an email to the following address airtecnics@airtecnics.com

I accept and give my consent for the abovementioned purposes. (*)