Airtècnics logo
Air Curtains Ventilation Air Disinfection

Air Curtains Specialist - Industrial Ventilation

  • Català
  • English
  • Español

  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  Login

Air Curtains Specialist - Industrial Ventilation

  • Products
    • Air curtains
      Air curtains
    • Air purifier and disinfection units
      Air purifier and disinfection units
    • Air Handling Units
      Air Handling Units
    • Heat recovery units
      Heat recovery units
    • Ventilation units
      Ventilation units
    • Fan heaters
      Fan heaters
    • Axial fans
      Axial fans
    • Radial fans
      Radial fans
    • Centrifugal fans
      Centrifugal fans
    • In line fans
      In line fans
    • Exhaust fans units
      Exhaust fans units
    • Cross-flow fans
      Cross-flow fans
    • Filters and filter units
      Filters and filter units
    • Dampers and shutters
      Dampers and shutters
    • Rotary actuators
      Rotary actuators
    • Controllers
      Controllers
    • Pressure switches and sensors
      Pressure switches and sensors
    • See all products
  • Technology
    • Air curtains: Foundations

      • What is an air curtain?
      • Are air curtains effective?
      • How air curtains work?
      • Air curtains: Technology
      • Advantages and benefits of air curtains
      • Air curtains: Applications
      • Installation examples
      • Selection factors of air curtains
      • Air curtains control and regulation
      • Heat pump air curtains
      • EC air curtains
    • Airtècnics Air Curtains

      • Characteristics
      • R+D+i UPC university
      • Selection chart
      • Models and applications
      • Control and regulation
      • Accessories
    • OH Technology

      • Hydroxyl Radicals Technology
      • OH technology application sectors
      • What is OH technology for?
      • OH technology against bacteria: Tests
      • OH technology against viruses: Tests
      • Is OH technology effective in educational centers?
      • Safety of long-term exposure to hydroxyl radicals
    • Ventilation

      • Fans: Overview
      • Heat recovery: Overview
      • Heat recovery: Types
      • EC fans: Overview
      • EC fans: Advantages
      • Rotary actuators for dampers
      • Fan speed controllers
      • Air Handling Unit: Types AHU
      • ECFanGrid: overview
  • Novelties
    • News

      • The international ISH ventilation fair in Frankfurt becomes a showcase for Airtècnics air curtains
      • HVAC renovation with an ECFanGrid in a German Hospital
      • New Eurovent Guide: Save Energy with Efficient Air Curtains
      • Airtècnics adds an installation accessory for the Dam and Windbox air curtains
      • The Konstanz city hall commits to energy efficiency by installing an Airtècnics air curtain
      • Airtècnics is present at AHR Expo 2025
      • How to install air curtains?
      • Installation of a Rund Air Curtain at Crous Occitanie, Toulouse
    • Newsletters

      • Newsletter February 2025
      • Newsletter January 2025
      • Newsletter December 2024
      • Newsletter November 2024
      • Newsletter October 2024
      • Newsletter September 2024
      • Newsletter July 2024
      • Newsletter April 2024
    • Top Works

      • W hotel, Dubai (UAE)
      • Sheikh Jaber Al-Ahmad Cultural Centre, Kuwait (Kuwait)
      • Nike store, Milan (Italy)
      • Mango shop, Platja d'Aro (Spain)
      • Vodafone store, Barcelona (Spain)
      • Stratford station, London (United Kingdom)
      • Union Square building, Aberdeen (United Kingdom)
      • National Audit Office, London (United Kingdom)
  • Applications
    • Configuration and Selection Apps

      • Air Curtain Selection and Configuration Program
      • Air Curtain Reference Information
      • Air Curtain Spare parts
      • Air Curtain Accessories list
    • Calculations

      • Air Curtain Door Loss Calculation
      • Air Curtain Comparative AC vs EC
      • Air Curtain Comparative Electrical Heated vs Heat Pump
      • Air Curtain Equivalent water valve size
      • Heating Air temperature increasing
    • Product Illustration

      • Infographics - Virtual Product Applications
  • Gallery
    • Installations
    • Virtual Installations
    • Videos
  • References
  • Downloads
  • Company
    • Airtècnics
    • Staff
    • Rosenberg Group
    • Work with Us
  • Contact
    • Contact Us
    • Air Curtains Distributors
    • Air Purifier Distributors
  • Català
  • English
  • Español
  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  1. Home
  2. Technology
  3. Air curtains: Foundations
  4. Air curtains: Technology
Index
  • Air curtains: Foundations

    • What is an air curtain?
    • Are air curtains effective?
    • How air curtains work?
    • Air curtains: Technology
    • Advantages and benefits of air curtains
    • Air curtains: Applications
    • Installation examples
    • Selection factors of air curtains
    • Air curtains control and regulation
    • Heat pump air curtains
    • EC air curtains
  • Airtècnics Air Curtains

    • Characteristics
    • R+D+i UPC university
    • Selection chart
    • Models and applications
    • Control and regulation
    • Accessories
  • OH Technology

    • Hydroxyl Radicals Technology
    • OH technology application sectors
    • What is OH technology for?
    • OH technology against bacteria: Tests
    • OH technology against viruses: Tests
    • Is OH technology effective in educational centers?
    • Safety of long-term exposure to hydroxyl radicals
  • Ventilation

    • Fans: Overview
    • Heat recovery: Overview
    • Heat recovery: Types
    • EC fans: Overview
    • EC fans: Advantages
    • Rotary actuators for dampers
    • Fan speed controllers
    • Air Handling Unit: Types AHU
    • ECFanGrid: overview

Air curtains: Technology

It is known that on open doorways with two adjacent areas in different conditions the air is interchanged between them because the laws of physics tend to equalise the temperature and pressure difference between both sides.

Basically air transfer on doorways happens due to these 3 factors:

  • Temperature difference: is the natural convection effect that creates an air transfer between two areas with temperature difference. Warm air will escape through the top of the doorway and being replaced by cold air coming in at the bottom. As bigger temperature difference bigger air infiltrations and energy losses
  • Pressure difference: it is recommended to equilibrate the pressure difference as much as possible because it affects the air curtain performance. But in some installations like clean zones a little pressure difference helps to prevent the particles entering from outside
  • Wind, stack effect and draughts: by modifying the air jet strength and the outlet discharge angle, the air curtain can work against forced air movements like wind or draughts. But if the velocity of the incoming air is excessive the air curtain will become less efficient

Schematic representation of the main parameters involved in the performance of an air curtain produced by the UPC (Polytechnic University of Catalonia).
The efficiency of an air curtain depends on the optimization of performance factors.

air curtain performance parametersh = effective width of the jet
α = discharge angle
U0 = discharge velocity
θ = negative impact angle
H = opening height
P1 = outside pressure
P2 = inside pressure


The most important ones are:

Turbulence of the jet: low turbulence jet will be much more efficient and save energy
Air speed: air velocity should be enough across the doorway
Air volume: a wider jet makes the air curtain stronger against air transfer on doorways
Angle discharge: according to a situation if jets are well oriented it will increase the energy saving
Fan type: axial, tangential wheel, centrifugal, etc. Higher pressure fans create a higher pressure jet that reaches farther. For instance, if we compare an air curtain with tangential fan against an air curtain with centrifugal fan (with same air volume), the jet made of centrifugal fans will be stronger and larger.

UPC University air curtain studies have proven that air turbulences are one of the most important parameters that will affect the distance of the air jet.

UPC University schema shows the air turbulences behaviour:

air curtain turbulences
Optimized shape of the outlet plenum, the position and fans type, the shape of lamellas, etc. substantially affects the air jet performance.

Air curtains angle discharge

Tests and University studies have proven that the angle discharge helps substantially helps the air curtain to be more efficient.

When factors like wind, temperature or pressure difference causes air transfer from outside to inside, we can aim the jet towards outside some degree. Then the jet direction against the air entrance will help to keep the air outside. The trajectory of the jet will be parabolic but at the end will reach the floor approximate by the doorway. If we can’t adjust the angle discharge, the jet will be pushed in by the external air forces.

The forces parallelogram theory explains how the forces behave on a doorway. The following diagrams show the difference between air curtains with fixed lamellas against adjustable ones.

air curtain with fixed lamellas


Air curtain with fixed lamellas less efficient (1)

air curtain with oriented lamellas


Air curtain with oriented lamellas more efficient (2) 

(1) The first one, fixed vanes, where the entrance air velocity pushes the jet of the air curtain, the resultant of the parallelogram of forces is diverted inwards. This allows outside air to enter inside.

(2) The second one, adjustable lamellas, when the air jet is oriented against the entrance, the resultant of the parallelogram forces is directed perpendicularly to the floor. This means that outside air does not enter and inside air does not escape. Besides internal temperature level is maintained.

  Previous
Next  
Products
Air curtains
Air purifier and disinfection units
Air Handling Units
Heat recovery units
Ventilation units
Fan heaters
Axial fans
Radial fans
Centrifugal fans
In line fans
Exhaust fans units
Cross-flow fans
Filters and filter units
Dampers and shutters
Rotary actuators
Controllers
Pressure switches and sensors

Air Curtains
Standard air curtains
Recessed air curtains
Decorative, bespoke and customized air curtains
Air curtains with disinfection and purification system
Heat pump and energy saving air curtains
Industrial air curtains and cold store air curtains
Insect control air curtains
Revolving door and tailor made air curtains
Economic low cost air curtains

About us
Airtècnics history
Rosenberg group
Contact
Aircurtains Distributors
Air Purifier Distributors

Downloads
Air curtains catalogues
Ventilation catalogues
BIM Air Curtains
Air curtains price list
Technical documentation
Quality certificates

Featured content
Clever advanced control
Air curtains selection program
Air curtains installations: References
Air curtains photo gallery
Technology
What is an air curtain?
How air curtains work?
Advantages and benefits of air curtains
Heat pump air curtains
EC air curtains
Airtècnics air curtains
Ventilation

Outlet


Legal terms
Privacy policy
Legal notice
Conditions of sale
Cookies policy
+34 93 715 99 88 +34 93 715 99 88
airtecnics@airtecnics.com
We use our own and third-party cookies to analyze our services and show you advertising related to your preferences based on a profile made from your browsing habits (for example, pages visited). You can get more information and set your preferences HERE.