Airtècnics logo
Air Curtains Ventilation Air Disinfection

Air Curtains Specialist - Industrial Ventilation

  • Català
  • English
  • Español

  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  Login

Air Curtains Specialist - Industrial Ventilation

  • Products
    • Air curtains
      Air curtains
    • Air purifier and disinfection units
      Air purifier and disinfection units
    • Air Handling Units
      Air Handling Units
    • Heat recovery units
      Heat recovery units
    • Ventilation units
      Ventilation units
    • Fan heaters
      Fan heaters
    • Axial fans
      Axial fans
    • Radial fans
      Radial fans
    • Centrifugal fans
      Centrifugal fans
    • In line fans
      In line fans
    • Exhaust fans units
      Exhaust fans units
    • Cross-flow fans
      Cross-flow fans
    • Filters and filter units
      Filters and filter units
    • Dampers and shutters
      Dampers and shutters
    • Rotary actuators
      Rotary actuators
    • Controllers
      Controllers
    • Pressure switches and sensors
      Pressure switches and sensors
    • See all products
  • Technology
    • Air curtains: Foundations

      • What is an air curtain?
      • Are air curtains effective?
      • How air curtains work?
      • Air curtains: Technology
      • Advantages and benefits of air curtains
      • Air curtains: Applications
      • Installation examples
      • Selection factors of air curtains
      • Air curtains control and regulation
      • Heat pump air curtains
      • EC air curtains
    • Airtècnics Air Curtains

      • Characteristics
      • R+D+i UPC university
      • Selection chart
      • Models and applications
      • Control and regulation
      • Accessories
    • OH Technology

      • Hydroxyl Radicals Technology
      • OH technology application sectors
      • What is OH technology for?
      • OH technology against bacteria: Tests
      • OH technology against viruses: Tests
      • Is OH technology effective in educational centers?
      • Safety of long-term exposure to hydroxyl radicals
    • Ventilation

      • Fans: Overview
      • Heat recovery: Overview
      • Heat recovery: Types
      • EC fans: Overview
      • EC fans: Advantages
      • Rotary actuators for dampers
      • Fan speed controllers
      • Air Handling Unit: Types AHU
      • ECFanGrid: overview
  • Novelties
    • News

      • The international ISH ventilation fair in Frankfurt becomes a showcase for Airtècnics air curtains
      • HVAC renovation with an ECFanGrid in a German Hospital
      • New Eurovent Guide: Save Energy with Efficient Air Curtains
      • Airtècnics adds an installation accessory for the Dam and Windbox air curtains
      • The Konstanz city hall commits to energy efficiency by installing an Airtècnics air curtain
      • Airtècnics is present at AHR Expo 2025
      • How to install air curtains?
      • Installation of a Rund Air Curtain at Crous Occitanie, Toulouse
    • Newsletters

      • Newsletter February 2025
      • Newsletter January 2025
      • Newsletter December 2024
      • Newsletter November 2024
      • Newsletter October 2024
      • Newsletter September 2024
      • Newsletter July 2024
      • Newsletter April 2024
    • Top Works

      • W hotel, Dubai (UAE)
      • Sheikh Jaber Al-Ahmad Cultural Centre, Kuwait (Kuwait)
      • Nike store, Milan (Italy)
      • Mango shop, Platja d'Aro (Spain)
      • Vodafone store, Barcelona (Spain)
      • Stratford station, London (United Kingdom)
      • Union Square building, Aberdeen (United Kingdom)
      • National Audit Office, London (United Kingdom)
  • Applications
    • Configuration and Selection Apps

      • Air Curtain Selection and Configuration Program
      • Air Curtain Reference Information
      • Air Curtain Spare parts
      • Air Curtain Accessories list
    • Calculations

      • Air Curtain Door Loss Calculation
      • Air Curtain Comparative AC vs EC
      • Air Curtain Comparative Electrical Heated vs Heat Pump
      • Air Curtain Equivalent water valve size
      • Heating Air temperature increasing
    • Product Illustration

      • Infographics - Virtual Product Applications
  • Gallery
    • Installations
    • Virtual Installations
    • Videos
  • References
  • Downloads
  • Company
    • Airtècnics
    • Staff
    • Rosenberg Group
    • Work with Us
  • Contact
    • Contact Us
    • Air Curtains Distributors
    • Air Purifier Distributors
  • Català
  • English
  • Español
  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  1. Home
  2. Technology
  3. Ventilation
  4. EC fans: Overview
Index
  • Air curtains: Foundations

    • What is an air curtain?
    • Are air curtains effective?
    • How air curtains work?
    • Air curtains: Technology
    • Advantages and benefits of air curtains
    • Air curtains: Applications
    • Installation examples
    • Selection factors of air curtains
    • Air curtains control and regulation
    • Heat pump air curtains
    • EC air curtains
  • Airtècnics Air Curtains

    • Characteristics
    • R+D+i UPC university
    • Selection chart
    • Models and applications
    • Control and regulation
    • Accessories
  • OH Technology

    • Hydroxyl Radicals Technology
    • OH technology application sectors
    • What is OH technology for?
    • OH technology against bacteria: Tests
    • OH technology against viruses: Tests
    • Is OH technology effective in educational centers?
    • Safety of long-term exposure to hydroxyl radicals
  • Ventilation

    • Fans: Overview
    • Heat recovery: Overview
    • Heat recovery: Types
    • EC fans: Overview
    • EC fans: Advantages
    • Rotary actuators for dampers
    • Fan speed controllers
    • Air Handling Unit: Types AHU
    • ECFanGrid: overview

EC fans: Overview

EC stands for Electronically Commutated, and it combines AC and DC voltages bringing the best of both worlds.

The motor runs on a DC voltage, but with a single phase 230VAC or three phase 400VAC supply. The motor incorporates voltage transformation within the motor.

The non-rotating part of the motor (stator) is extended to make room for an electronic PCBoard which includes power transformation AC to DC, as well as the controls.

fan ec

An EC motor (Electronically Commutated) is a brushless, direct current, external rotor type of motor. In commutation electronics, an AC voltage is changed into a direct voltage by a commutator.

The motor position is dependent upon voltage supplied via an inverter module (similar to the principle of a frequency inverter).

The EC commutation electronics are different from a frequency inverter in that they decide how the motor phases in the stator are supplied with current (commutation) depending on position, rotation direction and default.

fan ec diagram

Permanent magnets in the rotor produce a magnetic field which is required for full load production. A high efficiency, low noise, and continuous motor speed control is possible with this. An assembly flange on the rotor is used for impeller assembly. Depending on the motor type, a terminal box is available with cable screw connections or connection cable for easy and quick connection. Depending on the application area is possible to adopt further control functions (e.g. constant pressure control, volume flow control, temperature control).

Conventional DC motors have a housing which contains all the assembly groups like carbon brushes, the collector, bearing, armature with winding, etc. They are arranged one after another. With the EC motor assembly, more space is saved and a collector and carbon brush are not necessary. Therefore the motor is significantly shorter and consequently has advantages with regard to dimensions when installing and quiet operation.

The slightly higher investment costs for EC fans in comparison with conventional motors are mostly amortized within the shortest operation time because of the low energy consumption and lower installation costs (no transformer control, frequency inverter, or phased angle control is necessary).

  Previous
Next  
Products
Air curtains
Air purifier and disinfection units
Air Handling Units
Heat recovery units
Ventilation units
Fan heaters
Axial fans
Radial fans
Centrifugal fans
In line fans
Exhaust fans units
Cross-flow fans
Filters and filter units
Dampers and shutters
Rotary actuators
Controllers
Pressure switches and sensors

Air Curtains
Standard air curtains
Recessed air curtains
Decorative, bespoke and customized air curtains
Air curtains with disinfection and purification system
Heat pump and energy saving air curtains
Industrial air curtains and cold store air curtains
Insect control air curtains
Revolving door and tailor made air curtains
Economic low cost air curtains

About us
Airtècnics history
Rosenberg group
Contact
Aircurtains Distributors
Air Purifier Distributors

Downloads
Air curtains catalogues
Ventilation catalogues
BIM Air Curtains
Air curtains price list
Technical documentation
Quality certificates

Featured content
Clever advanced control
Air curtains selection program
Air curtains installations: References
Air curtains photo gallery
Technology
What is an air curtain?
How air curtains work?
Advantages and benefits of air curtains
Heat pump air curtains
EC air curtains
Airtècnics air curtains
Ventilation

Outlet


Legal terms
Privacy policy
Legal notice
Conditions of sale
Cookies policy
+34 93 715 99 88 +34 93 715 99 88
airtecnics@airtecnics.com
We use our own and third-party cookies to analyze our services and show you advertising related to your preferences based on a profile made from your browsing habits (for example, pages visited). You can get more information and set your preferences HERE.