Airtècnics logo
Air Curtains Ventilation Air Disinfection

Air Curtains Specialist - Industrial Ventilation

  • Català
  • English
  • Español

  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  Login

Air Curtains Specialist - Industrial Ventilation

  • Products
    • Air curtains
      Air curtains
    • Air purifier and disinfection units
      Air purifier and disinfection units
    • Air Handling Units
      Air Handling Units
    • Heat recovery units
      Heat recovery units
    • Ventilation units
      Ventilation units
    • Fan heaters
      Fan heaters
    • Axial fans
      Axial fans
    • Radial fans
      Radial fans
    • Centrifugal fans
      Centrifugal fans
    • In line fans
      In line fans
    • Exhaust fans units
      Exhaust fans units
    • Cross-flow fans
      Cross-flow fans
    • Filters and filter units
      Filters and filter units
    • Dampers and shutters
      Dampers and shutters
    • Rotary actuators
      Rotary actuators
    • Controllers
      Controllers
    • Pressure switches and sensors
      Pressure switches and sensors
    • See all products
  • Technology
    • Air curtains: Foundations

      • What is an air curtain?
      • Are air curtains effective?
      • How air curtains work?
      • Air curtains: Technology
      • Advantages and benefits of air curtains
      • Air curtains: Applications
      • Installation examples
      • Selection factors of air curtains
      • Air curtains control and modulation
      • Heat pump air curtains
      • EC air curtains
    • Airtècnics Air Curtains

      • Characteristics
      • R+D+i UPC university
      • Selection chart
      • Models and applications
      • Control and regulation
      • Accessories
    • OH Technology

      • Hydroxyl Radicals Technology
      • OH technology application sectors
      • What is OH technology for?
      • OH technology against bacteria: Tests
      • OH technology against viruses: Tests
      • Is OH technology effective in educational centers?
      • Safety of long-term exposure to hydroxyl radicals
    • Ventilation

      • Fans: Overview
      • Heat recovery: Overview
      • Heat recovery: Types
      • EC fans: Overview
      • EC fans: Advantages
      • Rotary actuators for dampers
      • Fan speed controllers
      • Air Handling Unit: Types AHU
      • ECFanGrid: overview
  • Novelties
    • News

      • Airtècnics commitment with the environment
      • Airtècnics obtains part of the financing for AMCA and CSA certifications thanks to the Cámara de Comercio Española
      • Airbox air handling unit for high-performance industrial kitchen in Germany
      • How to cool server rooms?
      • Rotowind air curtain with special mountings in an international hotel in London
      • Twin KPL air curtain for cold chambers in food industry in France
      • New low industrial air curtains range of Airtècnics
      • New finish catalog for the Zen and Rund air curtain
    • Newsletters

      • Newsletter May 2025
      • Newsletter April 2025
      • Newsletter March 2025
      • Newsletter February 2025
      • Newsletter January 2025
      • Newsletter December 2024
      • Newsletter November 2024
      • Newsletter October 2024
    • Top Works

      • W hotel, Dubai (UAE)
      • Sheikh Jaber Al-Ahmad Cultural Centre, Kuwait (Kuwait)
      • Nike store, Milan (Italy)
      • Mango shop, Platja d'Aro (Spain)
      • Vodafone store, Barcelona (Spain)
      • Stratford station, London (United Kingdom)
      • Union Square building, Aberdeen (United Kingdom)
      • National Audit Office, London (United Kingdom)
  • Applications
    • Configuration and Selection Apps

      • Air Curtain Selection and Configuration Program
      • Air Curtain Reference Information
      • Air Curtain Spare parts
      • Air Curtain Accessories list
    • Calculations

      • Air Curtain Door Loss Calculation
      • Air Curtain Comparative AC vs EC
      • Air Curtain Comparative Electrical Heated vs Heat Pump
      • Air Curtain Equivalent water valve size
      • Heating Air temperature increasing
    • Product Illustration

      • Infographics - Virtual Product Applications
  • Gallery
    • Installations
    • Virtual Installations
    • Videos
  • References
  • Downloads
  • Company
    • Airtècnics
    • Staff
    • Rosenberg Group
    • Work with Us
  • Contact
    • Contact Us
    • Air Curtains Distributors
    • Air Purifier Distributors
  • Català
  • English
  • Español
  • Dansk
  • Deutsch
  • Dutch
  • Eesti keel
  • Français
  • Italiano
  • Latvian
  • Magyar
  • Norwegian
  • Polskie
  • Português
  • Pусский
  • Slovenščina
  • Suomalainen
  • Srpskohrvatski
  • Svenska
  • Türkçe
  • čeština
  1. Home
  2. Novelties
  3. News
  4. Most common mistakes in air curtain installations

Most common mistakes in air curtain installations

Sunday 21 February 2021

The main causes of an ineffective air curtain are that the air curtain is not adapted to the special conditions required for each installation, but it is also a problem when the installation is not carried out according to the specifications of the air curtain in question.

First, the curtain must be located close to the entrances so that the airflow forms a barrier in the gap left by the opening door. Depending on the model, the curtain can be recessed, hanging or fixed to the wall or floor, vertical.

The curtain must have enough space around the motors so that the air can flow quite easily and does not encounter barriers, so that the curtain can perform its functions as efficiently as possible.

 

Air curtain too near of ceiling with no space to absorb enough air
Air curtain too near of ceiling with no space to absorb enough air.

 

Another common problem is the lack of maintenance of the curtains. Although they are not units that need very specific maintenance, it is important to comply with minimum hygienic requirements such as cleaning the suction grid, for example.

When the grid accumulates a large amount of dust, this ends up being deposited on the fans and inside the unit, generating a large amount of dirt that compromises the optimal functioning of the device.

 

Filthy air curtain and smaller than the door
Filthy air curtain and smaller than the door.

 

A very common mistake is to install a curtain with a smaller span than the door for which it is intended, which generates gaps through which the outside air passes. In this way, the installation of the curtain is no longer effective and what is supposed to be an investment ends up being a waste, as the purpose of the curtain, which is to save energy, is not fulfilled.

Cold rooms and large freezers require specific air curtains for low temperatures: Triojet System and Kool. Both are designed to be installed outside the cold room, above the door and without any kind of obstacle in front of the air jet. In addition, it is ideal to install space separator panels together with the curtain to create an intermediate environment for the air curtain to work even more effectively, avoiding freezing or accumulation of condensation inside the unit.

In general, a very common mistake is to resort to assembly companies that do not specialise in curtain installations because, due to lack of knowledge or laziness, they do not follow the specific assembly instructions for each model and each situation. The installation of an air curtain requires a highly specialised profile in the installer in order to ensure that the investment is effective and the benefits are optimally returned.

 

 

Insect control air curtain installed upside down. The jet should be closer to the door.
Air curtain installed upside down. The jet emits air horizontally and the suction grille points to the floor.
ZEN curtain installed in a beam as if it were "recessed".
Air curtain designed to be installed in a false ceiling.
Air jet above a rail, no air flow possible.
Previous Next
  Previous
Share:
Next  

Related News

Airtècnics air curtains at the stations of Haramain, the high-speed railway from Medina to Mecca

Miniatura-Noticia.jpg

Majestic project for connecting the Muslim holy cities of Medina and Mecca is called the Haramain. It consists of a new 453-kilometre high-speed railway infrastructure that runs through the King Abdullah city in Rabigh, King Abdulaziz International Airport and Jeddah city centre. Overall, five extra large and modern stations in the Saudi Arabia ...

The importance of control and regulation for air curtains

Miniatura.jpg

In recent years, air curtains have become an essential solution for many sectors, from retail to manufacturing. Designed primarily to maintain separation of climate zones, reduce energy consumption and improve indoor air quality, air curtains have established themselves as a valuable investment. But beyond their correct installation, proper ...

Installation of Airtècnics air curtains in the sumptuous W Dubai The Palm hotel

Miniatura-Noticia.jpg

An exclusive oasis is where the modern geometric architecture of the luxurious W Dubai The Palm hotel rises, between the Persian Gulf's water and wide private beaches. The innovative wavy shape project includes about a hundred thousand square meters accommodations, of which 300 hotel rooms and 45 luxury super duplex apartments, triplex apartments ...

Other News

Airtècnics air curtains for CaixaBank stores

airtecnics-air-curtains-caixabank-offices-(Miniatura).jpg

CaixaBank, one of the main Spanish Banks, has trusted Airtècnics air curtains for its new store concept. The new Bank offices adapt to the current customer needs, creating a more technological, open and accessible space in order to improve the user experience.In this case, in order to maintain an unitary design line, CaixaBank has ...

Airtècnics obtains AMCA certification for Windbox and Zen air curtains

Imatge-Noticia.jpg

Airtècnics has reached a significant milestone by obtaining AMCA certification for its Windbox and Zen air curtain models. This certification, in accordance with the ANSI/AMCA 220 Standard, confirms the air flow rate, average outlet velocity, outlet velocity uniformity, velocity projection, and power rating at free delivery through ...

Air handling units for any applications

Miniatura.jpg

Ventilation systems always have different requirements. In some installations it is simply necessary an air exchange, whereas in others the requirements of temperature, humidity and air purity can be very demanding. Airtècnics designs the air handling units according to the particularities of each project with highly configurable modules. ...

Fans for railway applications

Ventilación-aplicaciones-ferroviarias.jpg

Airtècnics offers a complete range of fans for railway applications and provides efficient and high quality solutions, adequate to the specific characteristics of each vehiche used in ferrovial transportation. Several manufacturers and suppliers from the ferrovial industry trust the fans designed and manufactured by Rosenberg Group. High ...

Related News

Airtècnics air curtains at the stations of Haramain, the high-speed railway from Medina to Mecca

Miniatura-Noticia.jpg

Majestic project for connecting the Muslim holy cities of Medina and Mecca is called the Haramain. It consists of a new 453-kilometre high-speed railway infrastructure that runs through the King Abdullah city in Rabigh, King Abdulaziz International Airport and Jeddah city centre. Overall, five extra large and modern stations in the Saudi Arabia ...

The importance of control and regulation for air curtains

Miniatura.jpg

In recent years, air curtains have become an essential solution for many sectors, from retail to manufacturing. Designed primarily to maintain separation of climate zones, reduce energy consumption and improve indoor air quality, air curtains have established themselves as a valuable investment. But beyond their correct installation, proper ...

Products
Air curtains
Air purifier and disinfection units
Air Handling Units
Heat recovery units
Ventilation units
Fan heaters
Axial fans
Radial fans
Centrifugal fans
In line fans
Exhaust fans units
Cross-flow fans
Filters and filter units
Dampers and shutters
Rotary actuators
Controllers
Pressure switches and sensors

Air Curtains
Standard air curtains
Recessed air curtains
Decorative, bespoke and customized air curtains
Air curtains with disinfection and purification system
Heat pump and energy saving air curtains
Industrial air curtains and cold store air curtains
Insect control air curtains
Revolving door and tailor made air curtains
Economic low cost air curtains

About us
Airtècnics history
Rosenberg group
Contact
Aircurtains Distributors
Air Purifier Distributors

Downloads
Air curtains catalogues
Ventilation catalogues
BIM Air Curtains
Air curtains price list
Technical documentation
Quality certificates

Featured content
Clever advanced control
Air curtains selection program
Air curtains installations: References
Air curtains photo gallery
Technology
What is an air curtain?
How air curtains work?
Advantages and benefits of air curtains
Heat pump air curtains
EC air curtains
Airtècnics air curtains
Ventilation

Outlet


Legal terms
Privacy policy
Legal notice
Conditions of sale
Cookies policy
+34 93 715 99 88 +34 93 715 99 88
airtecnics@airtecnics.com

Request more information

The message been successfully submitted.

Request more information

If you want more information, fill the form and we contact with you.






Check this box if you like to receive professional information.

In accordance with the established RGPD (General Data Protection Regulation), we inform you that your personal data collected by means of this form will be incorporated in a file held by MOTORS I VENTILADORS, S.L., which has the purpose of enabling the management and commercial relations, informative or contractual and in any form and medium, including electronic means, about the products and/or services you are interested in. Your data will not be disclosed to third parties without your consent expressly stated, except in cases provided by law or requisitions of the competent public Administration.

You therefore expressly authorise us to use and process your personal data for the aforementioned purposes.

At any time, you may exercise your rights of access, rectification, erasure, restriction of processing, portability and object of your personal data processing. We request that you notify us to MOTORS I VENTILADORS, S.L. C/ Conca de Barberà, 6, Pol. Ind. Pla de la Bruguera 08211 CASTELLAR DEL VALLÈS (Barcelona) or send an email to the following address airtecnics@airtecnics.com

I accept and give my consent for the abovementioned purposes. (*)
We use our own and third-party cookies to analyze our services and show you advertising related to your preferences based on a profile made from your browsing habits (for example, pages visited). You can get more information and set your preferences HERE.